Telematics and Automotive Infotainment Technologies |
![]() |
||||||||||||||||||||||||||||||||||||||||||||
![]() |
|||||||||||||||||||||||||||||||||||||||||||||
|
THE CNX-P1290 DUAL OUTPUT 90 WATT INTELLIGENT DC-DC POWER REGULATORFull-featured, sophisticated regulator compatible
with systems from Travla, Xenarc, Sumicom,
Cappucino and others
|
|||||||||||||||||||||||||||||||||||||||||||||
|
|
*+7.5V to +18VDC (+12V nominal*) |
|
Low
|
+10.5VDC nominal |
|
Low
|
Vin < 10.5VDC for more than 10 seconds |
|
Input Fuse |
15 Amp ATM mini-fuse |
|
Input Protection |
Over voltage transients |
|
Input Mating Connector |
Molex 39-01-3042 (pins 39-00-0212) |
|
Primary Output Voltage |
+12VDC +/-5% |
|
Primary Output Current |
6.3 Amps max. with short circuit protection |
|
Secondary Output Voltage |
+5VDC +/-5% |
|
Secondary Output Current |
3 Amps max. with short circuit protection |
|
Total Output Power |
90 Watts continuous at nominal +12VDC
input* |
|
Output Ripple |
10% of output voltage (120mVpp) |
|
Output Mating Connector |
Molex 39-01-2060 (pins 39-00-0121) |
|
Shutdown Delay Timer |
6 seconds (default), 15 minutes (optional),
(jumper selectable) |
|
Boot-up/Shut-down Lockout Time |
~45 seconds |
|
DelayOn Delay Time |
3 seconds after power applied to +12V
output |
|
DelayOn Output Current |
500mA max with self resetting fuse |
|
Operating
|
-10°C to +70°C |
|
Operating Efficiency |
~85% at maximum output current |
|
Case Dimensions |
3.8 inches x 3.0 inches x 1.5 inches
(L x W x H)
(76 mm x 97 mm x 39 mm) |
|
Warranty |
90 day limited warranty |
*The CNX-P1290 is designed to operate with a “nominal”
+12VDC input from a car battery or alternator. This input voltage can vary significantly
from a low of +7.5VDC during engine cranking at cold temperatures, to +18VDC during
jump starting or abnormal alternator “spikes”. The CNX-P1290 can operate under full
load (90 Watts output) with an input voltage of less than +10.5VDC for the duration
of engine cranking. It is NOT designed to take a continuous input voltage of less
than +12VDC for an extended period of time while under heavy load. If the input
voltage drops below +10.5VDC for more than 10 seconds, the CNX-P1260 shutdown controller
will go into “Forced Shutdown” mode which will turn off the CarPC after a 30 second
delay.
MSRP: $94.95USD